• Vol. 26 No. 7, 401–404
  • 01 July 1997

Photorefractive Keratectomy for the Treatment of Compound Myopic Astigmatism Using the Ablatable Mask

, , , ,

Eight eyes of 8 patients with compound myopic astigmatism were treated with excimer laser photorefractive keratectomy (PRK) using a hand-held ablatable mask in conjunction with the Summit excimer laser. The attempted correction ranged from -1.25 to -4.00 dioptres (D) of astigmatism and 0 to -8.00 D of myopia. All eyes had attained at least 6 months of postoperative follow-up. Five of the 8 eyes achieved an unaided visual acuity of 6/12 or better. Postoperative refractions ranged from -0.50 to -3.50 D of refractive cylinder and from +0.50 to -3.75 D of spherical error. Decentration of the ablation zone was encountered in 3 eyes due to shifts in patients’ fixation. Technical difficulty with the use of the hand-held ablatable mask limited the widespread application of this procedure and it has now been superseded by newer excimer laser systems which can correct astigmatism without having to employ a mask. Despite this, because of the theoretical ability of the mask to correct any form of refractive error, the concept of the mask shape transfer process will remain as a potential alternative in refractive surgery, especially for correction of hyperopia and hyperopic astigmatism.

This article is available only as a PDF. Please click on “Download PDF” on top to view the full article.

Declaration

The author(s) declare there are no affiliations with or involvement in any organisation or entity with any financial interest in the subject matter or materials discussed in this manuscript.